Furan Based Graphite Mortar

GLOBE FGC MORTAR (Furan Graphite Mortar) is a specially formulated Furan based Graphite cement for chemicals resistant tiles and bricks construction. Especially in jacketed chemical reactors.

Field Of Application

GLOBE FGC MORTAR (Furan Graphite Cement) is recommended for tile & brick lining in Tanks, Jacketed, Vessels, Receivers, Reactors requiring the chemical, physical and thermal heat transfer properties. Temperature resistivity is upto 200°c. 

Chemical Resistance

GLOBE FGC MORTAR is resistant to organic acid, solvent, oils, greases and salts. It is also resistant to many inorganic acids and alkalis. GLOBE FGC MORTAR complies with the specifications of ASTM for chemicals resistant furan resin mortars.

Properties

  • High chemicals resistance, particularly to acids, alkalies and certain solvents.
  • High temperature resistance upto 200°C
  • Lower shrinkage in furan resins
  • Electrically conductive, wherever required.
  • Long shelf life even at higher temperature. Approx. 24 Months.
  • High Mechanical strength.
  • Highly Conductive Cement & Heat transfer for cooling & heating is good. 

Available Colours

GLOBE FGC MORTAR is available in black colour only.

Physical & Chemical Properties

PropertyUnitTest MethodTypical Value
Densitygms/cc.
ASTM C9051.70 to 1.80 
Bond strength 7 days @(250C)N/mm2
ASTM C3211.20 to 1.80 
Tensile Strength 7 days @(250C)N/mm2
ASTM C3076 to 8 
Compressive Strength 7 days @(250C)N/mm2
ASTM C579Above 50 
Flexural Strength 7 days @(250C)N/mm2
ASTM C580Above 10 
Coefficient of Thermal Expansion (K-1)
ASTM C5312.8 x 10-5 Co-efficient
Water Absorption
ASTM C413Less than 1%
Temperature Resistance°C
-180 °C Maximum.
Linear Shrinkage
ASTM C3210.5%
Chemical Resistance (for Phosphoric Acid & Other Acids/Alkalies)
-Loss of wt. <1% Resistance to all acids/alkalies. (Excellent performance )
Working Time
-30 to 50 mins.
Setting Time
-120-180 mins.
Ratio of Powder to Resin
-1: 1
Thermal conductivity
-Good

Mixing Of The FGC Mortar

Mixing of the components should be with mixer with  5 kg. mortar capacity. The mixing speed should be between 50-60 RPM.Stir the content of the resin container prior to blending. The amount of the poser may be carried slightly to obtain the desired consistency. Proportionally increase or decrease component as per batch size requirement. Mixing of material may be possible manually into the metal pot container as per required quantity to be used for lining purpose. A thick black gravy solution will be recommended for lining with ratio 1:1 (Powder to liquid) approximately. 

Pot Life

TemperatureGlobe Carbon Mortar (Globe FGC)
27 °CApprox. 35 Mins. ±10 mins.

Consumption

Bedding and jointing (Bedding 5-7mm / jointing 2-3 mm)

MaterialDimensionsConsumption
Tiles230x115x12Apprx. 10 kg. /m2
Tiles230x115x20Apprx. 13 kg. /m2
Tiles230x115x25Apprx. 15 kg. /m2
Bricks230x115x40Apprx. 18 kg. /m2
Bricks230x115x50Apprx. 20 kg. /m2
Bricks230x115x65Apprx. 21 kg. /m2
Bricks230x115x80Apprx. 22 kg. /m2
Bricks230x115x100Apprx. 24 kg. /m2


Storage & Shelf Life

The resin & mortar should be kept in cool & dry place tightly closed, away from moisture, heat & direct sunlight. For safety reasons keep both resin & powder away from each other. Both the materials have a shelf life of min. 24 months as recommended conditions. In case the ambient Temp. is more than 30-35°C, the shelf life of above materials will get reduced accordingly.

Health & Safety

Adequate ventilation is to be provided while work is in progress. Ventilation is compulsory for all work carried out in pits and closed rooms. All vapours that are produced while work is in progress must be continuously suctioned off at floor or bottom level. Mostly the mixing of mortar is to be carried out at open surface. Only the amount of material effectively required to continue work is to be stored at working place. The instruction for the prevention of fire and explosion are to be observed, if required. Please note and ensure that, even the smallest quantities of the individual components and/or pre-prepared mixtures are not allowed to reach the sewerage. All regulation for the prevention of accidents prescribed at the site of application & surface treatment in rooms and tanks, as well as the safety precautions listed on the packing (label) required by the provisions of the Hazardous Materials ordinance shall be adhered.